|
Name |
Product show |
Description |
Remarks |
430DPL-D2 Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-D2 Continuous Process Analyzer for Hydrogen and Dew Point - 430DPL Model The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording.
|
|
430DPL-PMN7 Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-PMN7 Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA7 Sensor Housing with Panel Mounted Control Cabinet (Two Separate Enclosures) The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording. |
|
430DPL-N7MC Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-N7MC Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA7 UL/CSA Explosion-proof with Magnetic Calibration, Meets Class1 Div1 Group B,C,D Rating The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording. |
|
430DPL-RM Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-RM Continuous Process Analyzer for Hydrogen and Dew Point, 19" (483mm) Rack Mounted on Sliding Rails The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording. |
|
430DPL-N12 Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-N12 Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted,NEMA12 (IP52) Enclosure Rating The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording. |
|
430DPL-N4X Continuous Process Analyzer for Hydrogen and Dew Point |
|
430DPL-N4X Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted,Corrosion-resistant,NEMA4X (IP56) Enclosure Rating The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as a recorder output. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. For dew point, the 430DPL has a capacitive ceramic sensor. The output of this sensor is directly proportional to the dew point of the sample gas. After the sample gas has been analyzed for H2 and dew point, both signals are amplified and displayed on digital meters and are provided as voltage or current outputs for recording. |
|