|
Name |
Product show |
Description |
Remarks |
257N12 Continuous Dew Point Analyzer |
|
257N12 Continuous Dew Point Analyzer, Wall mounted,NEMA 12 (IP52) enclosure rating The Nova 257 Series Continuous Dew Point Analyzers have been designed primarily for accurate dew point measurement of exothermic or endothermic heat treating atmospheres. The dielectric polymer sensor provides stable and accurate dew point measurements and is not affected by most gas compositions. A built in sample pump draws in samples that are of insufficient pressure from the process. The sample flow is shown on a small rotameter with valve. The analyzer then reads the dew point continuously. |
|
256RM Continuous Analyzer For Low Range Dew Point |
|
256RM Continuous Analyzer For Low Range Dew Point, 19" (483 mm) rack mounted The Nova 256 Series Continuous Analyzers for Low Range Dew Point have been designed primarily for accurate dew point analysis of heat treating atmospheres, instrument air, or other applications which may have typical dew points that are lower than what can be read by standard dew point analyzers, such as the Nova 257 Series. The dielectric polymer sensor provides stable and accurate measurements and is not affected by most gas compositions, except those containing SO2, SO3 and HCl. |
|
256N4 Continuous Analyzer For Low Range Dew Point |
|
256N4 Continuous Analyzer For Low Range Dew Point, Wall mounted NEMA 4 (IP65) The Nova 256 Series Continuous Analyzers for Low Range Dew Point have been designed primarily for accurate dew point analysis of heat treating atmospheres, instrument air, or other applications which may have typical dew points that are lower than what can be read by standard dew point analyzers, such as the Nova 257 Series. The dielectric polymer sensor provides stable and accurate measurements and is not affected by most gas compositions, except those containing SO2, SO3 and HCl. |
|
256N12 Continuous Analyzer For Low Range Dew Point |
|
256N12 Continuous Analyzer For Low Range Dew Point, Wall mounted NEMA 12 (IP52) The Nova 256 Series Continuous Analyzers for Low Range Dew Point have been designed primarily for accurate dew point analysis of heat treating atmospheres, instrument air, or other applications which may have typical dew points that are lower than what can be read by standard dew point analyzers, such as the Nova 257 Series. The dielectric polymer sensor provides stable and accurate measurements and is not affected by most gas compositions, except those containing SO2, SO3 and HCl.
|
|