362K便携式烟气分析仪 |
|
362K便携式烟气分析仪,氧气,一氧化碳和氮氧化物,手提箱(K)外壳 The Nova 362 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. Model 362 has customer-replaceable sensors, which respond quickly to the O2, CO, and NOx present in the flue gas sample. The sensor life expectancy is between 3-4 years. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter, flow meter, and then on to the three sensors. The detected O2, CO, and NO are displayed on separate LCD digital meters, which have a switchable backlight for use in dark areas. The analyzer can be operated for long periods unattended. The Nova 362 can also optionally indicate net stack temperature for doing fuel efficiency calculations (362T). The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED indicates when to recharge and a green LED verifies that it is receiving recharging power. The battery recharger is included with the analyzer. The rugged dust-tight and water resistant case is ideal for use in harsh environments. |
|
362WP便携式烟气分析仪 |
|
362WP便携式烟气分析仪,氧气,一氧化碳和氮氧化物,防水(WP)外壳 The Nova 362 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. Model 362 has customer-replaceable sensors, which respond quickly to the O2, CO, and NOx present in the flue gas sample. The sensor life expectancy is between 3-4 years. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter, flow meter, and then on to the three sensors. The detected O2, CO, and NO are displayed on separate LCD digital meters, which have a switchable backlight for use in dark areas. The analyzer can be operated for long periods unattended. The Nova 362 can also optionally indicate net stack temperature for doing fuel efficiency calculations (362T). The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED indicates when to recharge and a green LED verifies that it is receiving recharging power. The battery recharger is included with the analyzer. The rugged dust-tight and water resistant case is ideal for use in harsh environments. |
|
375K便携式烟气分析仪 |
|
375K便携式烟气分析仪,氧气,一氧化碳,二氧化碳,手提箱(K)外壳 The Nova 375 Series Portable Flue Gas Analyzers have been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The sensors respond quickly to oxygen, CO2, and CO present in the flue gas sample. The O2 and CO sensor life expectancy is between 3 and 4 years. The CO2 infrared detector life is infinite under normal conditions of use, unless contaminated. The O2 and CO sensors are customer-replaceable. The infrared CO2 detector should not need to be replaced. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. (4 m) sample hose, condensate removal filter, secondary filter and flow meter and then on to the three sensors. The detected O2, CO2 and CO are displayed on digital meters which have a switchable backlight for use in dark areas. A special water separating filter and seperate drain pump continuously remove condensate from the sample so the analyzer can be operated for long periods unattended. The Nova 375T version also indicates stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included. |
|
375WP便携式烟气分析仪 |
|
375WP便携式烟气分析仪,氧气,一氧化碳,二氧化碳,防水(WP)外壳 The Nova 375 Series Portable Flue Gas Analyzers have been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The sensors respond quickly to oxygen, CO2, and CO present in the flue gas sample. The O2 and CO sensor life expectancy is between 3 and 4 years. The CO2 infrared detector life is infinite under normal conditions of use, unless contaminated. The O2 and CO sensors are customer-replaceable. The infrared CO2 detector should not need to be replaced. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. (4 m) sample hose, condensate removal filter, secondary filter and flow meter and then on to the three sensors. The detected O2, CO2 and CO are displayed on digital meters which have a switchable backlight for use in dark areas. A special water separating filter and seperate drain pump continuously remove condensate from the sample so the analyzer can be operated for long periods unattended. The Nova 375T version also indicates stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included. |
|
376K便携式烟气分析仪 |
|
376K便携式烟气分析仪,氧气,一氧化碳,二氧化碳,氮氧化物,手提箱(K)外壳 The Nova 376 Series Portable Analyzers provide a detailed analysis of flue gas composition. They have been designed for accuracy, reliability, and ease of use and service. The sensors respond quickly to the gases of interest present in the flue gas sample. Under normal conditions of use, the O2, CO and NOx sensors each have a life expectancy of between 3 and 4 years and are customer-replaceable. The CO2 sensor should not need to be replaced. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. (4 m) sample hose, condensate removal filter, secondary filter and flowmeter, and then on to the four sensors. The detected O2, CO2, CO, and NOx are displayed on digital meters which have a switchable backlight for use in dark areas. The sensors do not require special SO2 scrubbing chemicals as do some types of analyzers. The Nova 376T version also indicates stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power.
|
|
376WP便携式烟气分析仪 |
|
376WP便携式烟气分析仪,氧气,一氧化碳,二氧化碳,氮氧化物,防水(WP)外壳 The Nova 376 Series Portable Analyzers provide a detailed analysis of flue gas composition. They have been designed for accuracy, reliability, and ease of use and service. The sensors respond quickly to the gases of interest present in the flue gas sample. Under normal conditions of use, the O2, CO and NOx sensors each have a life expectancy of between 3 and 4 years and are customer-replaceable. The CO2 sensor should not need to be replaced. In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. (4 m) sample hose, condensate removal filter, secondary filter and flowmeter, and then on to the four sensors. The detected O2, CO2, CO, and NOx are displayed on digital meters which have a switchable backlight for use in dark areas. The sensors do not require special SO2 scrubbing chemicals as do some types of analyzers. The Nova 376T version also indicates stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided. A rechargeable 'gel cell' battery provides enough power for about 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. |
|
|
|