名稱 |
產品展示 |
說明 |
備註 |
380WP便攜式三氫淨化氣體分析儀 |
|
380WP便攜式三氫淨化氣體分析儀,防水(WP)外殼 The Nova 380 Series Tri-Gas Analyzer is designed for monitoring H2 purity inside a power generator and to monitor the purging procedure during a generator shut down or start up.The analyzer contains a temperature compensated thermal conductivity (T/C) cell, amplifier board, digital readout, range switch, pressure regulator, gas flow control valve, pump and a flow indictor. A recorder output is optional. The T/C cell does not burn the sample nor is it consumed in any way, so it has a life expectancy of over 10 years. Measurement results are fast and accurate. A rechargeable 'gel cell' battery provides enough power for about 8 hours of continuous operation and the analyzer can be used while it is being recharged. |
|
335K便攜式氫氣過程分析儀 |
|
335K便攜式氫氣過程分析儀,手提箱(K)外殼 The Nova 335 Portable Analyzer has been designed for the detection of hydrogen (H2) in a binary (two gas) mixture such as H2in N2. However, it can be used in some other applications with several background gases present. Consult Nova on these applications.The thermal conductivity (T/C) cell provides a fast and accurate measurement of H2. It has an expected life of over 10 years unless contaminated. In operation, a built in sample pump draws in the gas sample through the sample tube, filter and flow meter and then on to the T/C cell. The detected H2 is displayed on an LCD digital meter which has a switchable back light for use in dark areas. A rechargeable 'gel cell' battery provides enough power for approximately 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included. |
|
335WP便攜式氫氣過程分析儀 |
|
335WP便攜式氫氣過程分析儀,防水(WP)外殼 The Nova 335 Portable Analyzer has been designed for the detection of hydrogen (H2) in a binary (two gas) mixture such as H2in N2. However, it can be used in some other applications with several background gases present. Consult Nova on these applications.The thermal conductivity (T/C) cell provides a fast and accurate measurement of H2. It has an expected life of over 10 years unless contaminated. In operation, a built in sample pump draws in the gas sample through the sample tube, filter and flow meter and then on to the T/C cell. The detected H2 is displayed on an LCD digital meter which has a switchable back light for use in dark areas. A rechargeable 'gel cell' battery provides enough power for approximately 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included. |
|
430D2氫氣過程分析儀 |
|
430D2氫氣過程分析儀-430系列 The Nova 430 Series Process Hydrogen analyzer utilizes a temperature-controlled TC cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as an output recorder. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. |
|
430PMN7氫氣過程分析儀 |
|
430PMN7氫氣過程分析儀,壁掛式,配備安裝面板的NEMA7傳感器外殼 The Nova 430 Series Process Hydrogen analyzer utilizes a temperature-controlled TC cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as an output recorder. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. |
|
430N7MC氫氣過程分析儀 |
|
430N7MC氫氣過程分析儀,壁掛式,防護 NEMA7 UL/ CSA,非侵入式磁校準,防爆Class1,Div1,Group B,C,D The Nova 430 Series Process Hydrogen analyzer utilizes a temperature-controlled TC cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available as an output recorder. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement. |
|