名稱 |
產品展示 |
說明 |
備註 |
310K便攜式一氧化碳煙氣分析儀 |
|
310K便攜式一氧化碳煙氣分析儀,手提箱(K)外殼 The Nova 310 Series Portable Flue Gas CO Analyzer utilizes a reliable, customer-replaceable electrochemical sensor which responds quickly to the CO present in the flue gas sample. Its life expectancy is between 3 and 4 years.In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12ft sample house, condensate removal filter, secondary filter and flow meter then on to the CO detector. The detected CO is displayed on an LCD digital meter which has a switchable backlight for use in dark areas. A dual range switch allows either the 0-2000 PPM or the 0-4.00% range to be displayed. A rechargeable battery provides enough power to the pump and electronics for about 20 hours of continuous operation. The analyzer can still be operated while it is being charged. A red LED light on the front panel indicates when to recharge. A green LED lights indicates when the charge is complete. The analyzer is supplied with a 12 ft. (4 m) sample hose and a S.S. probe. |
|
310WP便攜式一氧化碳煙氣分析儀 |
|
310WP便攜式一氧化碳煙氣分析儀,防水(WP)外殼 The Nova 310 Series Portable Flue Gas CO Analyzer utilizes a reliable, customer-replaceable electrochemical sensor which responds quickly to the CO present in the flue gas sample. Its life expectancy is between 3 and 4 years.In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12ft sample house, condensate removal filter, secondary filter and flow meter then on to the CO detector. The detected CO is displayed on an LCD digital meter which has a switchable backlight for use in dark areas. A dual range switch allows either the 0-2000 PPM or the 0-4.00% range to be displayed. A rechargeable battery provides enough power to the pump and electronics for about 20 hours of continuous operation. The analyzer can still be operated while it is being charged. A red LED light on the front panel indicates when to recharge. A green LED lights indicates when the charge is complete. The analyzer is supplied with a 12 ft. (4 m) sample hose and S.S. probe. |
|
481D2一氧化碳連續過程分析儀 |
|
481D2一氧化碳連續過程分析儀,紅外探測器-481系列 The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal. |
|
481PMN7一氧化碳連續過程分析儀 |
|
481PMN7一氧化碳連續過程分析儀,紅外探測器,壁掛式,NEMA7傳感器外殼,面板安裝式控制櫃(兩個獨立的機櫃) The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal. |
|
481N7MC一氧化碳連續過程分析儀 |
|
481N7MC一氧化碳連續過程分析儀,紅外探測器,壁掛式,防護NEMA7 UL/ CSA,非侵入式磁校準,防爆Class1,Div1,Group B,C,D The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal. |
|
481RM一氧化碳連續過程分析儀 |
|
481RM一氧化碳連續過程分析儀,紅外探測器,19英寸(483毫米)支架式安裝在滑軌上 The Nova 481 Series CO analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flowmeter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent or PPM CO on the digital meter. The output is also available as an analog or digital signal. |
|
|
|