X51N Series Control Room Signal Conditioning

Model X51N Series -- Control Room Signal Conditioning [X51N]




Signal Conditioners with In-Circuit Calibration and High Panel Density Equals Lower Costs and Easier Installation 

  • RTD, T/C, mV, mA, V input transmitters, alarm trips, combination transmitter/trips and computational transmitters.
  • On-board plug-in sub-module facilitates change of range or sensor type.
  • Convenient front panel access to span, zero, and setpoint controls.
  • In-circuit calibration and input monitoring via front panel jacks,
  • without disconnecting the input or output wiring.
  • Signal to power supply isolation standard on all modules.
  • Input to output isolation on temperature transmitters.
  • Power On indicator on all modules.
  • Single and dual setpoint alarm trip and combination transmitter/alarm trips.
  • Plug and socket selection for relay operation and high or low setpoint.
  • Sensor failure detection without shutdown on RTD modules.
  • High density mechanical design, 20 modules in a standard 19 inch (48.25 cm) rack mount.

The Ronan X51N Series process signal conditioners, transmitters, alarm trips, and combination transmitter/trips, feature the most extensive selection of interface modules, providing high density packaging for the most economical price. The designs incorporate solidly based experience from the many thousands of installed and operating units, and offer superior performance based on today's technology and proven design techniques. The high density arrangement of the X51N Series, most suitable for system application in today's space-limited control rooms, is enhanced with the ultra high density combination of transmitter and alarm trip contained in the same module. These combination modules provide a unique solution to instrumentation requirements, where previously a transmitter and an alarm trip module occupied twice the space, thus providing an obvious economical advantage.

 Related Support Material : Model X51N Series -- Control Room Signal Conditioning
  Key: [L]
= Registration Required - [R] = Reps Only
Knowledge Base
No Records
FAQs
No Records
Documents
 
X51N 446 I&O Manual [L]
X51N Dual I&O Manual [L]
X51N Linear I&O Manual [L]
X51N 312 I&O Manual- [L]
X51N 312 I&O Manual (Short Form) [L]
X51N 472 I&O Manual [L]
X51AC I&O Manual [L]
X51 AC I&O Manual (Short Form) [L]
X51 Adder Subtractor I&O Manual [L]
X51 Adj. Ramp Buffer I&O Manual [L]
X51 Computations Transmitter I&O Manual [L]
X51 Frequency I&O Manual [L]
X51N 422 I&O Manual [L]
X51N RTD I&O Manual [L]
X51 Dual Channel Transmitter S. Manual [L]
 
X51N Brochure [L]
 
X51N-PS5 DataSheet[L]
X51N 400 Data Sheet [L]
X51N 300 Data Sheet [L]
X51N 422 Data Sheet[L]
X51N TC mv ma I&O Manual[L]

Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号