X120 Multiplexer/Termination Unit

Multiplexer/Termination Unit []


The Ronan Model X120 Multiplexer is designed to continuously monitor up to 48 dry field contacts,  voltage transmissions (live contacts), or solid state switching devices (SCR抯, Transistors, etc.). The unit transfers the status of all inputs, open or closed, alarmed or normal via serial communication to the receiver, a Digital Control System (DCS), Plant Computer, or Serial  Input Device such as the Ronan Model X110 Visual Annunciator Controller. The X120 features two types of  termination facilities, standard compression or quick  disconnect compression, allowing simple disconnect of an input for ground fault isolation or disabling a point.
 
The 48 inputs are optoisolated to provide isolation between input signals as well as field contact and logic voltage. The inputs are continuously scanned and their state transferred to the receiver via the Ronan proprietary protocol. For applications with more than 48 inputs, up to 32 Model X120 units can be daisy-chain connected to form a single serial output which monitors the status of up to 1536 dry or live contacts or solid state switching devices.
 
The input state changes are digitally filtered for 16 milliseconds before being transmitted over the high speed serial  communication line.
 
Each unit may be equipped with single or redundant power supplies for logic and field contact voltage. The power supplies are available for 115 VAC, 220 VAC, 50/60Hz and 24 VDC, 48 VDC or 125 VDC source. The field contact wetting voltage is 24 VDC or 125 VDC, providing total isolation between logic and field contact voltage. The X120 optionally features ground fault detection for every 24 inputs with LED indication and relay contact output.
 
Self-test, status, com. error, and loss of power is displayed by means of LED indicators. The loss of power supply voltage will de-energize the self-test relay. Manual input test for all 48 inputs may be initiated by depressing the reset pushbutton.  A failed input channel ID is transmitted to the host. Test failure and communication errors are indicated  on a LED and the horn relay will be activated.
Knowledge Base
No Records
FAQs
No Records
Documents
 
X120 I&O Manual [L]
 
X120 Multiplexer Brochure [L]
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号