Method of Detection | 
  | 
Electrochemical sensor for O2, infrared detector for CH4
  |  
  |  
Ranges Available | 
  | 
0-25.0% O2; any range between 0-50.0% and 0-100.0% CH4
  |  
  |  
Resolution | 
  | 
0.1% for O2 and CH4
  |  
  |  
Accuracy & Repeatability | 
  | 
±1% of full scale
  |  
  |  
Drift | 
  | 
Less than 2% of full scale per month
  |  
  |  
Response Time (T-90) | 
  | 
Less than 30 seconds not including sample line delay
  |  
  |  
Ambient Temperature Range | 
  | 
40°F to 104°F (4°C to 40°C), Optional: -22°F to 158°F (-30°C to 70°C) with Outdoor Packages
  |  
  |  
Linearity | 
  | 
±1% of full scale for each gas measured
  |  
  |  
Size & Weight | 
  | 
24" H x 24" W x 10" D @ 90 lbs (61 x 61 x 25 cm @ 20 kg)
  |  
  |  
Power | 
  | 
115 VAC 60 Hz (220 VAC 50 Hz available)
  |  
  |  
Output Options | 
  | 
Isolated 4-20 mA standard RS232, RS485, MODBUS®, Ethernet outputs optional
  |  
  |  
Alarms | 
  | 
High O2, low CH4, low flow; SPDT relays with 10A contacts
  |  
  |  
Analyzer Type | 
  | 
Landfill Gas Analyzer
  |  
  |  
Other Analysis Options | 
  | 
H1 - H2S, range 0 - 200 PPM H2 - H2S, range 0 - 2,500 PPM
  |  
  |  
Hazardous Area Rating Options | 
  | 
Class 1 Div 2 Class using purge kit system For H2 measurement - See 970 Series
  |  
  |   
  |    |  
 
 |  
For continuous analysis of oxygen (O2), methane (CH4), and/or carbon dioxide (CO2) in recovered gases from landfill and biogas sites. Hydrogen sulfide (H2S) readout optional. 
 
 
  |    |  
 
 |  
 A - BASE MODEL 
- Easy to use manual potentiometer calibration with LCD digital displays for each gas
 
- Temperature controlled sensors for maximum stability
 
- Long life electrochemical O2 sensor
 
- Infrared detector for reliable measurement of CO2 and CH4 (Models other than 910A or 910C). Detector may be cleaned in the field
 
- Stainless steel hard tubing and corrosion-resistant components for internal sample health
 
- Cabinet positive-pressure system to minimize the corrosive effects of hydrogen sulfide (H2S) on cabinet electronics & sensors
 
- Built in sample pump, pre-filter, filters, and flow meter
 
- Automatic moisture removal without the use of cooling water, compressed air or failure-prone thermal-electric elements
 
- Back pressure regulator to allow user to measure and minimize vacuum effects if the unit is vented back to the blower
 
- Rugged NEMA4 (IP65) enclosure
 
- Isolated 4 - 20 mA outputs for each gas
 
- Low flow alarm & relays
 
   C - AUTOCALIBRATION MODEL 
- Same features as Base model, plus:
 
- Automatic analyzer calibration with full-color touch screen LCD display
 
- Diagnostic alarms with troubleshooting guidance in display
 
- 'Cal Now' feature initiates full calibration with a single swipe of a magnetic wand
 
 
    |    |  
 
 |  
- H2S & BTU readouts (see ranges and models)
 
- Gas hi/low alarms with relay contacts
 
- RS232, RS485, MODBUS® and Ethernet outputs (available on Model C only)
 
- Class 1 Division 2 Group BCD rated purge kit for use in hazardous areas
 
- Outdoor weather package for operation from -22°F to 158°F (-30°C to 70°C)
 
- O2 measurement by paramagnetic detector
  
 
 
  |    |  
 
 |  
- Ambient air for O2 span and CO2 & CH4 zero
 
- Analyzed calibration gas of CO2 and CH4 in nitrogen for CO2 & CH4 span and O2 zero
   |    |     | 
							 
						  | 
					 | 
					
						 |