Specifications

Method of Detection

BTU - continuously calculated from the two flammable gases in the mixture
CO/CO2 - dual channel, high accuracy NDIR infrared detector
H2 - thermal conductivity sensor
N2 - continuously calculated by subtraction of other gases from 100%
O2 - customer replaceable electrochemical 'fuel cell' sensor

Ranges Available

Carbon Dioxide (CO2) - 0-50.0%
Carbon Monoxide (CO) - 0-50.0%
Hydrogen - 0-10.0% and 0-20.0%
Oxygen - 0-5.0%

Resolution

0.1% for all gases measured

Accuracy & Repeatability

±1% of full scale

Drift

Less than 2% of full scale per month

Response Time (T-90)

T90 < 30 seconds not including transmission time to process

Ambient Temperature Range

32 to 122°F (0 to 50°C), lower temperatures with cold weather package (to -20°C; -5°F)

Linearity

±1% of full scale

Size & Weight

Main Analyzer Cabinet Dimensions: 30" H x 24" W x 22" D (76 x 61 x 56 cm)

Power

115 VAC, 60 Hz
220 VAC, 60 Hz

Output Options

Ethernet and 4-20 mA output for all gases and alarm conditions

Alarms

Low Flow, Low Span1, Low Span 2, Low Zero and Hi cond. Temp. Also has calibration Fail Alarm

Analyzer Type

Blast Furnace Top Gas Analyzer

Hazardous Area Rating Options

Class 1, Div 2 Hazardous Area Rating


Applications
    Designed for the continuous monitoring of O2, CO, CO2, and/or H2 gases from blast furnaces or other continuous industrial processes where an uninterrupted stream of gas concentration data is critical. Calculated values of BTU, N2 and efficiency are also available.




Options
  • Cabinet purge system for use in dusty or hazardous locations
  • Cold weather package for operation to -5°F (-20°C)
  • Cabinet coolers can be fitted to most models




Unique Applications
    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.



Sample Conditioning
  • High capacity sample pump (where sample motivation is required) and high flow by-pass improves overall system response time
  • Compression-style moisture removal eliminates use of failure-prone Pelletier elements
  • Redundant heated filters allow user to remotely switch from a blocked filter to an unblocked filter, minimizing down time due to filter blockage.
  • Automatic blow back of heated filter and probe, can be sequenced with auto calibration, or based on sample vacuum limit
  • Digital control maintains constant sample flow even as filters start to plug, reducing operator required




Gas Analyzer
  • High accuracy gas detectors with full hydrogen compensation
  • Detection of CO & CO2 by reliable field cleanable non-dispersive infra red detector
  • Detection of O2 by long-life electrochemical sensor
  • Detection of H2 by thermal conductivity cell
  • Sensors mounted in temperature controlled 19" (48cm) rack mount drawer to reduce drift
  • Rack mounted sensor drawer, which is integral to the main cabinet, permits quick swap with replacement rack




Smart User Interface
  • Large graphical touch screen display
  • Auto calibration with user defined calibration frequency and purge duration
  • One-step 'CAL NOW' button allows full calibration without opening cabinet
  • Ethernet and 4-20mA outputs suitable for data collection by SCADA systems
  • Diagnostic alarms quickly notify operator of special faults
  • Diagnostic screen aids operator testing of gas analyzer
  • Troubleshooting guide aids operator in testing sample conditioning system and identifying parts to be changed
  • Maintenance alerts notify operators that filters should be checked or changed. Change frequency can be set by user
  • Password-protected user-adjustable parameters allow the operator to 'tweak' the operation of the analyzer without having to change the code
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号