Method of Detection |
|
Temperature controlled thermal conductivity (T/C) cell, cannot be burned out due to loss of flow or changing gases
|
|
Ranges Available |
|
Range 1 : 0-100% H2 in Air Range 2 : 0-100% H2 in CO2 Range 3 : 0-100% Air in CO2
|
|
Resolution |
|
±0.1% of gas measured
|
|
Accuracy & Repeatability |
|
±1% F.S except in 85-100% H2 in Air range which is within 0.2% absolute H2
|
|
Drift |
|
H2 in CO2 or Air in CO2 1% F.S. per week maximum drift, 0-100% H2 in Air range is ±0.2% per week
|
|
Response Time (T-90) |
|
10-15 seconds to 90% step change - not including sample transport time
|
|
Ambient Temperature Range |
|
0 to 49 ºC 32 to 122 ºF
|
|
Linearity |
|
±0.4% of F.S. on H2 in Air range, ±1% of F.S. in H2 or Air in CO2 ranges
|
|
Size & Weight |
|
Dimensions will vary depending on enclosure style and options required
|
|
Power |
|
115 VAC, 60 Hz 220 VAC, 50 Hz
|
|
Output Options |
|
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
|
|
Alarms |
|
Alarm set points are field adjustable Alarms have front panel light for each alarm and SPST (normally energized) relay with 5A rating at 250VAC non-inductive load Dual alarms are provided for low H2 purity. Detector fail alarm also provided as standard
|
|
Analyzer Type |
|
Tri-Gas Analyzer
|
|
Hazardous Area Rating Options |
|
Class 1, Div 2 Hazardous Area Rating
|
|
| |
|
For continuous analysis of hydrogen (H2) purity and for purge monitoring of hydrogen-cooled generators and synchronous converters.
| |
|
- One analyzer monitors all 3 gases for purity (Range 1) or purging (Ranges 2 and 3) :
- Range 1 : 0-100% H2 in Air
- Range 2 : 0-100% H2 in CO2
- Range 3 : 0-100% Air in CO2
- Best value continuous tri-gas analyzer
- Bright digital readout, 4-20 mA Outputs
- Long life electrochemical thermal conductivity cell with high accuracy and repeatability, cannot be burned out.
- Explosion proof gas detector enclosure suitable for Class 1 Division 1 Group BCD rated areas, UL/FM/CSA certified
- Fast response (T90 -10 to 15 secs)
- Easy to maintain modular layout
- Built in pressure regulator
| |
|
- Isolated analog, RS232, RS485, MODBUS and Ethernet output available options.
- Auto calibration option which includes the following features :
- Touch-screen display for easy entry of calibration gas settings, alarm set points, and calibration frequency
- One-touch 'cal-now' button (magnetic switch in explosion proof control cabinet) permits easy, and complete calibration without needing to open cabinet cover
| |
|
- Channel 1 - Air for Zero, 100% H2 for Span
- Channel 2 - 100% CO2 for Zero, 100% H2 for Span
- Channel 3 - 100% CO2 for Zero, Air for Span
| | |
|
|
|