Method of Detection |
 |
Microprocessor based infrared detector for CO2
|
 |
Ranges Available |
 |
0-20% CO2
|
 |
Resolution |
 |
0.1% CO2
|
 |
Accuracy & Repeatability |
 |
Within ±2% full scale
|
 |
Drift |
 |
Within 1% full scale per 8 hours of continuous operation
|
 |
Response Time (T-90) |
 |
30 - 40 seconds
|
 |
Ambient Temperature Range |
 |
0 to 40 ºC 32 to 105 ºF
|
 |
Linearity |
 |
Better than 1.0% of full scale
|
 |
Size & Weight |
 |
11 1/2" L x 8" H x 7 1/4" D @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)
|
 |
Power |
 |
AC/DC Operation, 115 VAC, 60 Hz for recharging
|
 |
Output Options |
 |
0-1 VDC 4-20 mA
|
 |
Alarms |
 |
High or low CO2 alarm with LED (optional)
|
 |
Hazardous Area Rating Options |
 |
General Purpose, Non-Hazardous
|
 |
| |
|
Analysis of carbon dioxide (CO2). For checking combustion efficiency, and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
| |
|
- Rugged design that is easy to operate
- Fast warm-up and response
- Solid state infrared detector
- Digital readout meter with backlight
- Modular layout that is easy to maintain
- Rechargeable battery operation
- Built in sample pump, filter and flowmeter
- Active condensate removal
- Weatherproof (WP) cabinet with clear Lexan cover
- Stainless steel probe with sample hose
| |
|
- Recorder outputs of 0-1 V or 4-20 mA (can be isolated)
- Stack temperature readout (302T)
- Special sampling probes
- Sample pre-cooler
- Suitcase (K) style cabinet available
- AC power only operation
- CO2 alarms with LED
- Data logger
| |
|
- Air for zero (except low range models which have a CO2 scrubber for zeroing).
- Analyzed CO2 cal gas for span.
| |