Method of Detection |
|
Customer replaceable zirconia O2 sensor. Expected life 5 years or more.
|
|
Ranges Available |
|
413 - any range from 0-2.0% to 0-96% O2 413L - any range from 0-200 PPM to 0-20000 PPM O2
|
|
Resolution |
|
0.1% O2 or % versions; 1 PPM O2 on PPM versions
|
|
Accuracy & Repeatability |
|
±0.5% of full scale
|
|
Drift |
|
Less than 0.3% of full scale per month
|
|
Response Time (T-90) |
|
2-3 seconds to 90% step change
|
|
Ambient Temperature Range |
|
32 to 122°F (0 to 50°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package
|
|
Linearity |
|
±0.5% of full scale
|
|
Size & Weight |
|
Dimensions will vary depending on enclosure style and options required
|
|
Power |
|
115 VAC, 60 Hz 220 VAC, 50 Hz
|
|
Output Options |
|
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
|
|
Alarms |
|
High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
|
|
Analyzer Type |
|
O2 Analyzer
|
|
Hazardous Area Rating Options |
|
General Purpose, Non-Hazardous
|
|
| |
|
For continuous analysis of PPM to 100% oxygen (O2) in process gas streams. Also recommended for other applications such as O2 enrichment of combustion air, oxygen deficiency analysis, and many more.
| |
|
- High accuracy continuous O2 analyzer
- Bright digital readout, and 4 - 20 mA outputs
- Long life zirconia O2 sensor
- Fast response (T90 - 2 to 3 seconds)
- Microprocessor control for push button calibration
- Easy-to-maintain modular layout
- Built in sample pump or pressure regulator
| |
|
- Hi/Low gas, low flow, and diagnostic alarms available
- Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
- Sample conditioning systems available for removal of moisture, acidic gas, and dust
- Cabinet purge system available for use in hazardous areas
- One-step 'cal-now' button with touch screen LCD display
- Full automatic calibration with touch screen LCD display
- Cold weather package for operation to -5°F (-20°C)
- Cabinet coolers can be fitted to most models
- High temperature filters and probes
| |
|
- Nitrogen for zero
- Air or analyzed calibration gas for span
| | |
|
|
|