Specifications

Method of Detection

Magneto-dynamic paramagnetic O2 cell

Ranges Available

412 - any range from 0-2.0% to 0-100.0% O2; 412HP - 98.0 to 100.0 or 0 to 100.00 O2

Resolution

412 - 0.1% O2; 412HP - 0.01% O2

Accuracy & Repeatability

±0.5% of full scale or 0.05%, whichever is greater

Drift

±0.2% of full scale per month

Response Time (T-90)

4-5 seconds

Ambient Temperature Range

32 to 122°F (0 to 50°C) @ 5-95% RH non-condensing. Lower temperatures (-5°F, -20°C) with Cold Weather Package. Sample dew point should be at least 9°F (5°C) below lowest sample temperature.

Linearity

±0.5% of full scale or 0.05%, whichever is greater

Size & Weight

Dimensions will vary depending on enclosure style and options required

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating

Analyzer Type

O2 Analyzer

Hazardous Area Rating Options

General Purpose, Non-Hazardous


Applications
    For continuous analysis of oxygen (O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.



Features
  • Highest accuracy O2 analyzer, very stable
  • Fast response (T90 - 4 to 5 seconds) and bright digital readout
  • Linear over entire 0-100% range
  • Microprocessor control for push button calibration
  • Non-consumable O2 detector, no periodic replacement required
  • Built in sample pump or pressure regulator, and 4 - 20 mA outputs
  • To improve accuracy, detector is mounted in temperature controlled heated box and compensated for changes in barometric pressure at the vent




Options
  • Hi/Low gas, low flow, and diagnostic alarms available
  • Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
  • Sample conditioning systems available for removal of moisture, acidic gas, and dust
  • Cabinet purge system available for use in hazardous areas
  • One-step 'cal-now' button with touch screen LCD display
  • Full automatic calibration with touch screen LCD display
  • Cold weather package for operation to -20°C (-4°F)
  • Cabinet coolers can be fitted to most models
  • High purity version available for 98-100% O2 (412HP)




Calibration
  • Nitrogen for zero
  • Air or analyzed calibration gas for span
Download
 
2010©Copyright  Combine instruments Co.,ltd allrights revered
USA:17888 67TH COURT NORTH LOXAHATCHEE FL 33470 US Post:FL33470
CHINA: No.40,JinFengXi Road,National Hi-Tech Industry Development Zone,ZhuHai,GuangDong,China
Tel:+0086 756 3895799 Fax:0086 756 3892788 E-mail:sales@combine-inst.com 

COMBINE INSTRUMENTS   Batching System  Loss-in-weight-feeder 
粤ICP备16107310号