|
|
|
名稱 |
產品展示 |
說明 |
備註 |
7900P-1AS便攜式氣體分析儀 |
|
7900P-1AS便攜式氣體分析儀,用於熱處理及其他氫基工業生產過程,單壹氣體分析儀,可燃氣體= CO x 2 The Nova Model 7900P Series Heat Treat analyzers utilize a three channel high stability infrared detector for the simultaneous measurement of CO, CO2, and CH4 in exothermic or endothermic gas mixtures. In addition, the analyzer can be supplied with a fully compensated thermal conductivity cell for H2. A separate O2 detector can also be supplied for measuring low (PPM) or percent levels of oxygen in the atmosphere gas stream. Dew point is detected by a dielectric ceramic sensor and is available in standard and low ranges. All detected gases have a separate LCD digital readout and a linear recorder output. The customer may choose any combination of gases to be measured.The 7900P series analyzers are complete with integral sampling pump, rechargeable battery, filters, flow meter, and sampling hose. Solenoid valves are used to isolate low range dew point and O2 sensors during purges and when analyzer is not in use to prevent ambient air contamination of the sensors and greatly reduce purge time during start-up. |
|
7900P-1A便攜式氣體分析儀 |
|
7900P-1A便攜式氣體分析儀,用於熱處理及其他氫基工業生產過程,單壹氣體分析儀,壹氧化碳 The Nova Model 7900P Series Heat Treat analyzers utilize a three channel high stability infrared detector for the simultaneous measurement of CO, CO2, and CH4 in exothermic or endothermic gas mixtures. In addition, the analyzer can be supplied with a fully compensated thermal conductivity cell for H2. A separate O2 detector can also be supplied for measuring low (PPM) or percent levels of oxygen in the atmosphere gas stream. Dew point is detected by a dielectric ceramic sensor and is available in standard and low ranges. All detected gases have a separate LCD digital readout and a linear recorder output. The customer may choose any combination of gases to be measured.The 7900P series analyzers are complete with integral sampling pump, rechargeable battery, filters, flow meter, and sampling hose. Solenoid valves are used to isolate low range dew point and O2 sensors during purges and when analyzer is not in use to prevent ambient air contamination of the sensors and greatly reduce purge time during start-up. |
|
8006-D2高爐爐頂煤氣分析儀 |
|
8006-D2高爐爐頂煤氣分析儀,H2,O2,CO,CO2,H2補償,N2,BTU和燃燒效率計算 The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these readings, other operating parameters such as nitrogen content, BTU and efficiency can be calculated and displayed. The analyzer consists of three main components : a heated filter cabinet which is directly mounted on the side of the blast furnace gas main, a sample conditioning system which is integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance.Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges. |
|
8002-D2高爐爐頂煤氣分析儀 |
|
8002-D2高爐爐頂煤氣分析儀,CO和CO2 The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these readings, other operating parameters such as nitrogen content, BTU and efficiency can be calculated and displayed. The analyzer consists of three main components : a heated filter cabinet which is directly mounted on the side of the blast furnace gas main, a sample conditioning system which is integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance.Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges. |
|
8004-D2高爐爐頂煤氣分析儀 |
|
8004-D2高爐爐頂煤氣分析儀,H2,O2,CO,CO2與H2補償 The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these readings, other operating parameters such as nitrogen content, BTU and efficiency can be calculated and displayed. The analyzer consists of three main components : a heated filter cabinet which is directly mounted on the side of the blast furnace gas main, a sample conditioning system which is integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance.Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges. |
|
8003-D2高爐爐頂煤氣分析儀 |
|
8003-D2高爐爐頂煤氣分析儀,H2,CO,CO2與H2賠償 The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these readings, other operating parameters such as nitrogen content, BTU and efficiency can be calculated and displayed. The analyzer consists of three main components : a heated filter cabinet which is directly mounted on the side of the blast furnace gas main, a sample conditioning system which is integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance.Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges. |
|
|
|