語言:       
高 品 質 產 品

專 業 化 服 務
 
  公司簡介
  產品目錄
  新聞中心
  支持與服務
  解決方案與應用
  銷售網絡
  聯繫我們

多氣體分析儀

        

名稱 產品展示 說明 備註
7903EN4氣體分析儀 7903EN4氣體分析儀,用於連續熱處理和工業工藝過程,三氣體分析儀,壹氧化碳,氫氣和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7903DN4氣體分析儀 7903DN4氣體分析儀,用於連續熱處理和工業工藝過程,三氣體分析儀,壹氧化碳,甲烷和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7903CN4氣體分析儀 7903CN4氣體分析儀,用於連續熱處理和工業工藝過程,三氣體分析儀,壹氧化碳,二氧化碳和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7903BN4氣體分析儀 7903BN4氣體分析儀,用於連續熱處理和工業工藝過程,三氣體分析儀,壹氧化碳,二氧化碳和氫氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7903AN4氣體分析儀 7903AN4氣體分析儀,用於連續熱處理和工業工藝過程,三氣體分析儀,壹氧化碳,二氧化碳和甲烷,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7902FN4氣體分析儀 7902FN4氣體分析儀,用於連續熱處理和工業工藝過程,雙氣體分析儀,氧氣和甲烷(氫氣和二氧化碳),壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
第一頁 前一頁 下一頁 最後一頁
 Go
2000©Copyright 2000 康寶萊儀表(珠海)有限公司 allrights revered
地址:中國廣東省珠海市(國家)高新技術産業開發區金峰西路40號
電話:+0086 756 3895799 傳真:0086 756 3892788 郵箱:sales@combine-inst.com  网站备案/许可证号:粤ICP备16107310号

配料系统  流量开关  流量计  称重事业部  失重喂料机(给料机) 珠海康宝莱