語言:       
高 品 質 產 品

專 業 化 服 務
 
  公司簡介
  產品目錄
  新聞中心
  支持與服務
  解決方案與應用
  銷售網絡
  聯繫我們

多氣體分析儀

        

名稱 產品展示 說明 備註
7461便攜式分析儀 7461便攜式分析儀,發動機廢氣,僅測CO
The 7460 Series Portable Analyzers are available in six versions for the simultaneous measurement of the gases typically found in the exhaust from internal combustion engines. CO, CO2, and HC's are detected by a dual-wavelength infrared detector. O2 and NOx (as NO) are detected by customer-replaceable electrochemical sensors. If NO2 analysis is selected, this is also by electro-chemical sensor.

All detector outputs are displayed on separate front panel digital meters. Optional built in printer, data logger and 4-20 mA recorder outputs are also available.

The 7460 Series Analyzers come complete with built in sampling pump, flow meter, automatic condensate removal, filters, PTFE liquid block, 12 ft. (4 m) sampling hose, and stainless steel probe. Also included are a cigarette lighter socket and remote printer actuator button for printer based models.

 
7905A氣體分析儀 7905A氣體分析儀,用於連續熱處理和工業工藝過程,- O2, CO, CO2, CH4, H2
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for H2 that is compensated for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. All sensors are temperature controlled or tempeature compensated for maximum stability. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic atmosphere gases, or for other industrial process gases. Calculations can be displayed such as gas ratios and heating value of flammable gases.
 
7904DN4氣體分析儀 7904DN4氣體分析儀,用於連續熱處理和工業工藝過程,四氣體分析儀,壹氧化碳,甲烷,氫氣和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7904CN4氣體分析儀 7904CN4氣體分析儀,用於連續熱處理和工業工藝過程,四氣體分析儀,壹氧化碳,二氧化碳,甲烷和氫氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7904BN4氣體分析儀 7904BN4氣體分析儀,用於連續熱處理和工業工藝過程,四氣體分析儀,壹氧化碳,二氧化碳,氫氣和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
7904AN4氣體分析儀 7904AN4氣體分析儀,用於連續熱處理和工業工藝過程,四氣體分析儀,壹氧化碳,二氧化碳,甲烷和氧氣,壁掛式,防護等級NEMA4(IP65)
The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4.This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
 
第一頁 前一頁 下一頁 最後一頁
 Go
2000©Copyright 2000 康寶萊儀表(珠海)有限公司 allrights revered
地址:中國廣東省珠海市(國家)高新技術産業開發區金峰西路40號
電話:+0086 756 3895799 傳真:0086 756 3892788 郵箱:sales@combine-inst.com  网站备案/许可证号:粤ICP备16107310号

配料系统  流量开关  流量计  称重事业部  失重喂料机(给料机) 珠海康宝莱