Method of Detection |
|
Customer replaceable electrochemical O2 and CO sensors
|
|
Ranges Available |
|
0-1800°F (0-1000°C) net stack temperature 0-25.0% O2, 0-2000 PPM to 0-4.00% CO (switch selectable)
|
|
Resolution |
|
0.1% O2, 1 PPM CO
|
|
Accuracy & Repeatability |
|
±1% of O2, ± 1 PPM CO
|
|
Drift |
|
±1% of full scale per 8 hours of continuous operation
|
|
Response Time (T-90) |
|
10-15 seconds for O2 and CO
|
|
Ambient Temperature Range |
|
0 to 40 ºC 32 to 105 ºF
|
|
Linearity |
|
±1% of full scale of each gas measured
|
|
Size & Weight |
|
10" L x 7 1/2" H x 8" D @ 8 lbs (25 x 19 x 20 cm @ 3.6 kg)
|
|
Power |
|
AC/DC Operation, 115 VAC 60 Hz for recharging (Other voltages available)
|
|
Output Options |
|
4-20 mA or 0-1 VDC
|
|
Alarms |
|
High CO alarm with LED
|
|
Hazardous Area Rating Options |
|
General Purpose, Non-Hazardous
|
|
| |
|
Analysis of oxygen (O2) and carbon monoxide (CO). For checking combustion efficiency, air infiltration, and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
| |
|
- Rugged design that is easy to operate and maintain
- Fast warm-up and response
- Digital readout meter with backlight
- Rechargeable battery operation
- Built in pump, filter, flow meter, and continuous condensate removal
- Weatherproof (WP) cabinet with clear Lexan cover
- Stainless steel probe with sample hose
- For use on any fuel
- Long life detector cells for O2 and CO (customer replaceable)
- Dual CO range: 0-2000 PPM and 0-4.00% CO
- Rapid CO reading recovery on CO 'overdose'
- Pays for itself in months through fuel savings
| |
|
- Recorder outputs of 0-1 V or 4-20 mA
- stack temperature readout (360T)
- Special sampling probes
- Sample pre-cooler
- Suitcase (K) style cabinet available
- AC power only operation, with HD sample pump
- High CO alarm with LED
- Detachable/portable data logger
| |
|
- Air for O2 span and CO zero
- Analyzed mixture of CO in nitrogen for CO span and O2 zero
| |
|
|
|
|