語言:       
高 品 質 產 品

專 業 化 服 務
 
  公司簡介
  產品目錄
  新聞中心
  支持與服務
  解決方案與應用
  銷售網絡
  聯繫我們




Specifications

Method of Detection

Infrared detector for CH4

Ranges Available

Any range between 0-50.0% and 0-100.0% CH4

Resolution

0.1% CH4

Accuracy & Repeatability

±1% of full scale

Drift

Less than 2% of full scale per month

Response Time (T-90)

Less than 30 seconds not including sample line delay

Ambient Temperature Range

40°F to 104°F (4°C to 40°C), Optional: -22°F to 158°F (-30°C to 70°C) with Outdoor Packages

Linearity

±1% of full scale for each gas measured

Size & Weight

24" H x 24" W x 10" D @ 90 lbs (61 x 61 x 25 cm @ 20 kg)

Power

115 VAC 60 Hz (220 VAC 50 Hz available)

Output Options

Isolated 4-20 mA standard
RS232, RS485, MODBUS®, Ethernet outputs optional

Alarms

low CH4, low flow; SPDT relays with 10A contacts

Analyzer Type

Landfill Gas Analyzer

Other Analysis Options

H1 - H2S, range 0 - 200 PPM
H2 - H2S, range 0 - 2,500 PPM

Hazardous Area Rating Options

Class 1 Div 2 Class using purge kit system
For H2 measurement - See 970 Series


Applications
    For continuous analysis of oxygen (O2), methane (CH4), and/or carbon dioxide (CO2) in recovered gases from landfill and biogas sites. Hydrogen sulfide (H2S) readout optional.




Features

A - BASE MODEL
  • Easy to use manual potentiometer calibration with LCD digital displays for each gas
  • Temperature controlled sensors for maximum stability
  • Long life electrochemical O2 sensor
  • Infrared detector for reliable measurement of CO2 and CH4 (Models other than 910A or 910C). Detector may be cleaned in the field
  • Stainless steel hard tubing and corrosion-resistant components for internal sample health
  • Cabinet positive-pressure system to minimize the corrosive effects of hydrogen sulfide (H2S) on cabinet electronics & sensors
  • Built in sample pump, pre-filter, filters, and flow meter
  • Automatic moisture removal without the use of cooling water, compressed air or failure-prone thermal-electric elements
  • Back pressure regulator to allow user to measure and minimize vacuum effects if the unit is vented back to the blower
  • Rugged NEMA4 (IP65) enclosure
  • Isolated 4 - 20 mA outputs for each gas
  • Low flow alarm & relays

C - AUTOCALIBRATION MODEL
  • Same features as Base model, plus:
  • Automatic analyzer calibration with full-color touch screen LCD display
  • Diagnostic alarms with troubleshooting guidance in display
  • 'Cal Now' feature initiates full calibration with a single swipe of a magnetic wand



Options
  • H2S & BTU readouts (see ranges and models)
  • Gas hi/low alarms with relay contacts
  • RS232, RS485, MODBUS® and Ethernet outputs (available on Model C only)
  • Class 1 Division 2 Group BCD rated purge kit for use in hazardous areas
  • Outdoor weather package for operation from -22°F to 158°F (-30°C to 70°C)
  • O2 measurement by paramagnetic detector




Calibration
  • Ambient air for O2 span and CO2 & CH4 zero
  • Analyzed calibration gas of CO2 and CH4 in nitrogen for CO2 & CH4 span and O2 zero
相關下載
 
2000©Copyright 2000 康寶萊儀表(珠海)有限公司 allrights revered
地址:中國廣東省珠海市(國家)高新技術産業開發區金峰西路40號
電話:+0086 756 3895799 傳真:0086 756 3892788 郵箱:sales@combine-inst.com  网站备案/许可证号:粤ICP备16107310号

配料系统  流量开关  流量计  称重事业部  失重喂料机(给料机) 珠海康宝莱