Method of Detection |
 |
CO (low-range), NO, NO2 and O2 by long life electrochemical sensor. CO (standard range), CO2, and HC by infrared detector
|
 |
Ranges Available |
 |
0-10.00% CO (special low range PPM CO available) 0-20.0% CO2 0-2000 PPM NOx (as NO) 0-2000 to 0-20,000 PPM HC's (as propane or hexane) 0-25.0% O2 0-800 PPM NO2
|
 |
Resolution |
 |
0.1% on % gas, 1 PPM on PPM gas
|
 |
Accuracy & Repeatability |
 |
?% of full scale for O2, CO, CO2 and HC's ?% of full scale for NOx
|
 |
Drift |
 |
<?% in 8 hours after full warmup
|
 |
Response Time (T-90) |
 |
8-10 seconds
|
 |
Ambient Temperature Range |
 |
0 to 40 篊
|
 |
Linearity |
 |
?.0% of full scale each gas measured
|
 |
Size & Weight |
 |
K Style - Approx. 14" W x 6" H x 10 1/2" D (35.5 x 15.2 x 26.6 cm), 12 lbs (5.5 kg)
|
 |
Power |
 |
115 VAC, 50/60 Hz for recharging 12 VDC for cigarette lighter socket 220 VAC, 50/60 Hz for recharging
|
 |
Output Options |
 |
0-1 VAC 4-20 mA Isolated 4-20 mA, RS232, RS485
|
 |
Options |
 |
Add NO (as NO) to any analyzer (add 'N' suffix) Add NO2 to any analyzer (add 'X' suffix) Analog 4-20 mA outputs Bench top (BT) style cabinet Built in printer (add 'P' suffix) Data logger for PC computer PPM CO in place of '%' (add 'L' suffix) Wallmount version with active condensate removal (QN4)
|
 |
Analyzer Type |
 |
Engine Exhaust Analyzer
|
 |
PRIMARY GAS to be Measured |
 |
Carbon Monoxide (CO) Hydrocarbons (HC's)
|
 |
| |
|
For checking engine exhaust emissions for diesel, gasoline, propane, or natural gas powered 2 and 4 cycle engines. Analysis of Carbon Monoxide (CO), Hydrocarbons (HC抯), Carbon dioxide (CO2), Oxygen (O2), Oxides of Nitrogen (NOx), Nitric Oxide (NO), and Nitrogen dioxide (NO2).
| |
|
- Rugged design that is easy to operate and maintain
- Fast warm up and accurate response
- Large digital readouts with back light for each gas
- Simple to operate, compact size
- Solid state infrared detectors for CO, CO2, and HC's
- Rechargeable battery operation (recharge from vehicle or from AC adapter)
- Provided with sample filter, and flexible sample probe with 12 ft. of hose, built in sample pump and automatic condensate removal
- Meets Bar 97 and OIML specifications
- Suitcase (K) style cabinet
| |
|
- Analog 4-20 mA outputs
- Built in printer (add 'P' suffix)
- Data logger for PC computer
- Add NO (as NO) to any analyzer (add 'N' suffix)
- Add NO2 to any analyzer (add 'X' suffix)
- PPM CO in place of '%' (add 'L' suffix)
- Bench top (BT) style cabinet
- Wallmount version with active condensate removal (QN4)
| |
|
|
|
|