Method of Detection | 
  | 
Single cell NDIR with no moving parts
  |  
  |  
Ranges Available | 
  | 
420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-500, 0-1000, 0-3000, 0-5000, PPM CO
  |  
  |  
Resolution | 
  | 
0.1% CO2 on % versions, 1 PPM CO2 on PPM versions
  |  
  |  
Accuracy & Repeatability | 
  | 
1% of full scale
  |  
  |  
Drift | 
  | 
Less than 1% of full scale per month
  |  
  |  
Response Time (T-90) | 
  | 
Less than 15 seconds
  |  
  |  
Ambient Temperature Range | 
  | 
40 to 122°F (5 to 50°C), Lower temperatures (-5°F, -20°C) available with Cold Weather Package
  |  
  |  
Linearity | 
  | 
±1% of full scale
  |  
  |  
Size & Weight | 
  | 
Physical data will vary depending on enclosure style and options required
  |  
  |  
Power | 
  | 
115 VAC, 60 Hz 220 VAC, 50 Hz
  |  
  |  
Output Options | 
  | 
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
  |  
  |  
Alarms | 
  | 
High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
  |  
  |  
Analyzer Type | 
  | 
CO2 Gas Analyzer
  |  
  |  
Hazardous Area Rating Options | 
  | 
Class 1, Div 1, Grp A-D Hazardous Area Rating
  |  
  |   
  |    |  
 
 |  
For continuous analysis of carbon dioxide (CO2) in process gas streams using an infrared detector. Percent and PPM levels available as Models 420 & 420L respectively. 
 
 
  |    |  
 
 |  
- PPM or percent CO2 by infrared detector
 
- Detector is sensitive, very reliable, and non-depleting
 
- Bright digital readout, 4-20 mA outputs
 
- Fast response (T90 - less than 15 seconds)
 
- Microprocessor control for push button calibration
 
- Easy-to-maintain modular layout
 
- Built in sample pump, flowmeter and filters
  
 
 
  |    |  
 
 |  
- Hi/Low gas, low flow, and diagnostic alarms available
 
- Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
 
- Sample conditioning systems available for removal of moisture, acidic gas, and dust
 
- Cabinet purge system available for use in hazardous areas
 
- One-step 'cal-now' button with touch screen LCD display
 
- Full automatic calibration with touch screen LCD display
 
- Cold weather package for operation to -5°F (-20°C)
 
- Cabinet coolers can be fitted to most models
 
- Sensor mounted in temperature controlled heated box to improve accuracy
 
- High temperature filters and probes
  
 
 
  |    |  
 
 |  
- Easily zero checked on ambient air or nitrogen (N2)
 
- Span using a known CO2 in nitrogen calibration gas.
   |    |     
 | 
   
 
        
         | 
         | 
        
           |