Specifications

Method of Detection

Customer replaceable zirconia O2 sensor. Expected life 5 years or more.

Ranges Available

413 - any range from 0-2.0% to 0-96% O2
413L - any range from 0-200 PPM to 0-20000 PPM O2

Resolution

0.1% O2 or % versions; 1 PPM O2 on PPM versions

Accuracy & Repeatability

±0.5% of full scale

Drift

Less than 0.3% of full scale per month

Response Time (T-90)

2-3 seconds to 90% step change

Ambient Temperature Range

32 to 122°F (0 to 50°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package

Linearity

±0.5% of full scale

Size & Weight

Dimensions will vary depending on enclosure style and options required

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Low flow alarm

Analyzer Type

O2 Analyzer

Hazardous Area Rating Options

Class 1, Div 2 Hazardous Area Rating


Applications
    For continuous analysis of PPM to 100% oxygen (O2) in process gas streams. Also recommended for other applications such as O2 enrichment of combustion air, oxygen deficiency analysis, and many more.



Features
  • High accuracy continuous O2 analyzer
  • Bright digital readout, and 4 - 20 mA outputs
  • Long life zirconia O2 sensor
  • Fast response (T90 - 2 to 3 seconds)
  • Microprocessor control for push button calibration
  • Easy-to-maintain modular layout
  • Built in sample pump or pressure regulator




Options
  • Hi/Low gas, low flow, and diagnostic alarms available
  • Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
  • Sample conditioning systems available for removal of moisture, acidic gas, and dust
  • Cabinet purge system available for use in hazardous areas
  • One-step 'cal-now' button with touch screen LCD display
  • Full automatic calibration with touch screen LCD display
  • Cold weather package for operation to -5°F (-20°C)
  • Cabinet coolers can be fitted to most models
  • High temperature filters and probes




Calibration
  • Nitrogen for zero
  • Air or analyzed calibration gas for span